Short Name |
APP:MISC:CVE-2018-10594-BO |
---|---|
Severity |
Major |
Recommended |
No |
Category |
APP |
Keywords |
Delta Electronics Delta Industrial Automation AHSIM_5x0 Simulator Buffer Overflow |
Release Date |
2018/07/31 |
Update Number |
3087 |
Supported Platforms |
idp-4.0+, isg-3.0+, j-series-9.5+, mx-11.4+, srx-12.1+, srx-branch-12.1+, vmx-17.4+, vsrx-12.1+, vsrx3bsd-18.2+ |
This signature detects attempts to exploit a known vulnerability against Delta Electronics Delta Industrial Automation AHSIM_5x0 Simulator. A successful attack can lead to arbitrary code execution.
Delta Industrial Automation COMMGR from Delta Electronics versions 1.08 and prior with accompanying PLC Simulators (DVPSimulator EH2, EH3, ES2, SE, SS2 and AHSIM_5x0, AHSIM_5x1) utilize a fixed-length stack buffer where an unverified length value can be read from the network packets via a specific network port, causing the buffer to be overwritten. This may allow remote code execution, cause the application to crash, or result in a denial-of-service condition in the application server.